Seta
Multi Method Flash Point Tester
MultiFlash is a universal fully
automated instrument designed for testing the flash point of
fuels, lubricating oils, solvents, chemicals, waste materials
and many other substances. The instrument comprises a
universal base unit that houses the display, control and data
acquisition functions, and a series of interchangeable modules
that allow the implementation of the required standard test
methods. MultiFlash is ruggedly designed to provide
simple and reliable operation and is specifically engineered
to ensure a very low cost of maintenance.
Multi
Flash 34100 shown with Pensky Martens Module
Also available are modules for Abel, Cleveland Open Cup,
TAG and Small Scale methods. (click on picture to
enlarge)
Pensky-Martens
(A and B Closed Cup)
ASTM D93; IP 34; IP 404; ASTM E502; BS 2000 Parts 34 and 404;
ISO 2719; EN 22719; JIS K2265; NF M07-019; DIN 51758; FTMS
791b 1102;
EPA 1010
Abel (Closed Cup
and Equilibrium)
IP 170; ISO 13736; EN 13736; BS 2000 Part 170; IP 304 Parts 1
and 2; IP 491; IP 492; ISO 1516; ISO 1523; BS3900 Parts A8 and
A9;
BS 6664 Parts 1 and 2
Tag (Closed Cup)
ASTM D56; D3941; D3934; E502; IP 304 parts 1 and 2; IP 491; IP
492; ISO 1516; ISO 1523; FTMS 791b 1101; JIS K2265
Cleveland (Open
Cup)
ASTM D92; IP 36; ISO 2592; EN 22592; BS 2000 Parts 36 and 403;
DIN 51376; T60-118; JIS K2265; AASHTO T48
Small Scale
Rapid Equilibrium (Setaflash) Closed Cup
ASTM D3278; ASTM3828; IP 303 Parts 1 and 2; ISO 3679; ISO
3680; BS 6664 Parts 3 and 4; BS 3900 Part A13; BS EN 456;
ASTM E502; UN Class 3 Non-viscous Flammable Liquids; CHIPS
Regulations; Classification of Dangerous Goods for Carriage:
Viscous and
Non-viscous liquids; EPA 1020 A and B; IP / ASTM Automatic
Small Scale draft method
EASE OF
OPERATION
MultiFlash operation is microprocessor controlled. A backlit
alphanumeric / graphics display and control panel provides a
simple user interface using 2 buttons and the Seta
Multifunctional And Rotational Test (SMART) control feature.
The SMART control is exceptionally easy to use for setting
modes of operation, temperatures, parameters and calibration.
PRECISE TEST
RESULTS
Platinum Resistance Thermometers are used exclusively
throughout MultiFlash to ensure accuracy, reliability and
robustness. Verification or re-calibration of all instrument
parameters is simple but secure.
WIDE TEST
TEMPERATURE RANGE
Electrical heating provides precise and reliable test
temperatures for all modules. An integral cooling fan assists
in preparing the instrument for the next test. Some modules
also allow the use of an external coolant supply to enable sub
ambient test temperatures, and to provide a fast cool down
facility at the end of the test.
INTERCHANGEABLE
TEST MODULES
MultiFlash test modules faithfully conform to the requirements
of the appropriate test method. Changing the test module
is straightforward and completed within a few minutes. The
module locates into an "intelligent" base unit, that
recognizes the module type and automatically sets up relevant
test parameters and calibration data. Each module includes a
DIPS pod (Dipping, Ignition, Pilot, Stirrer) containing the by
the test method).
GAS OR
ELECTRIC IGNITION OPTIONS
Electric Hot wire or gas ignition sources can be selected
from the control panel for all tests and modules. The
unique quick-fit coaxial igniter comprises a gas jet in
conformance with the requirements of the test method, and an
electric hot wire, which also ignites the gas jet when
required. The igniter is simple to change, low cost, and has a
long service life. For electric ignition the instrument
uses precision electronic control to ensure that the hot wire
provides a constant ignition temperature and prevents
premature failure. For gas ignition, an electrically
controlled valve automatically switches the gas supply on, and
the gas jet is ignited by the electric hot wire. An integral
rechargeable butane canister is supplied, however provision is
made for the use of an external gas supply if required.
AUTOMATIC
FLASH DETECTION
Automatic flash detection for the closed cup modules is
achieved using thermocouple technology which has proven to be
most effective for all products including bio-diesels and
those containing moisture. The Cleveland module is
fitted with an ionizing ring flash / fire detector that has
been universally proven and adopted for this open cup test.
SIMPLE
CONTROL FUNCTIONS
At the beginning of the test the sample is placed in the
cup and the lid is closed. The DIPS pod is brought into
mechanical contact with the cup / lid assembly by a simple
"push to engage" operation. A "start"
control initiates the test and the status is continuously
monitored with any problems or error conditions being shown on
the display.
AUTOMATIC
RESULT
At the end of the test the result is displayed, an audible
warning is given and the cup and associated heating system are
cooled down to a user defined temperature. On the Cleveland
module, a damper is deployed to extinguish any flame in the
cup. An integral electronic barometer automatically
corrects the flash point value in accordance with the mandated
equation that is included in all flash point methods.
The result and key test parameters are shown on the display
and may be transferred via an integral RS232 interface to a
printer or external computer. When connected to a printer the
test report includes a sequential test number and
identification. The last test result is stored in the
instrument and may be accessed from the control panel.
The SETALERT radio paging accessory can immediately alert the
operator of the end of the test or an operational problem.
INTEGRAL
DRAUGHT SCREEN
An opening transparent draught screen and a fixed
stainless steel rear screen is provided with each module. The
screens assist in obtaining consistent and accurate results
even when the MultiFlash is used in air conditioned
laboratories or under a fume hood. The transparent screen also
functions as a safety screen for the operator.
IN-BUILT
SAFETY
In the event of instrument over-temperature 3 independent
safety systems are automatically activated. The power supply
to the heating elements is isolated, the gas supply to the
igniter is shut off, and the cooling fan is switched on to
reduce the cup temperature.
RELIABLE
OPERATION AND EASE OF SERVICE
MultiFlash is designed to provide long and reliable operation.
Maintenance requirements are limited to replacement of service
components, such as the igniter, which is inexpensive and
quickly fitted.